Threaded Mount Pressure Transducer

MP56 and MP562

Introduction

Piezo-Metrics' Models MP56 and MP562 are miniature low-cost, general use transducers. These transducers are made of corrosive-resistant Titanium (6AL4V). They utilize high-reliability bulk type semiconductor strain gages bonded directly to the inside surface of the machined diaphragm.

Pressure on the diaphragm is applied through the hole in the nose which is then converted to an electric signal proportional to the pressure.

Applications

  • Test and Measurement Equipment
  • Product Equipment & controls
  • Energy Controls
  • Laboratory Instruments & Equipment
  • Liquip Level
  • Calibration Equipment
  • Hydraulic Controls
  • Features

  • Compact Size, fitted with 6th Cable.
  • Manufactured in Titanium, 6AL4V
  • Insensitive to screw down torque
  • Pressure ranges from 50 to 7000 psig
  • Threaded 1/4 NPT or 1/8 NPY
  • Model MP56 Constant Voltage 5 Vdc. Output 100 mVolts
  • Model MP562 Constant Current 4 to 20 mA

  • Performance options (All Value Maximum)

    A

    B

    C

    D

    Units

    Balance (Zero) MP56 ±3.00 ±2.00 ±2.00 ±2.00 mV mV
    Balance (Zero) MP562 4.00±0.50 4.00±0.30 4.00±0.20 4.00±0.20 mA
    Full Scale Sensitivity MP56 20.0±2.00 20.0±2.00 20.0±2.00 20.0±2.00 mV/V
    Full Scale Sensitivity MP562 20.0±0.50 20.0±0.30 20.0±0.20 20.0±0.20 mA
    Static Error Band ±0.50 ±0.25 ±0.25 ±0.25 %FS*BFSL
    Thermal Balance (Zero) Shift ±0.02 ±0.02 ±0.01 ±0.005 %FS/°F
    Thermal Sensitivity Shift ±0.02 ±0.02 ±0.01 ±0.005 %FS/°F
    Long Term Stability (less than) ±2.00 ±2.00 ±2.00 ±2.00 %FS/year
    *BFSL=Best Fit Straight Line

    Mechanical

    Standard Pressure Ranges 50, 100, 200, 300, 500, 1k, 2k, 3k, 5k, 7k, psi Gage
    Other ranges possible 10, 15, 25 psi Gage
    Other Pressure (No change out spec.) 2.0x Range
    Burst Pressure 6.0x Range
    Liquids Campatibility with Titanium, 6AL4V

    Environmental

    Storage and Operating temperature 0° - 180°F
    Compensated Temperature Range 30° - 130°F

    MP56 Electrical Performance mV Output

    Excitation 5 Volts Dc. or 10 Volts Dc.
    Maximum Voltage 50 V for Short Periods
    Input Resistance (Nominal) 1400±400 ohms
    Output Resistance (nominal) 850±200 ohms
    Insulation Resistance Minumum 50 M ohms @ 50VDC

    MP562 Electrical Performance mV Output

    Excitation 12 to 30 VDC
    Load Resistance 500 ohms - standard, see chart
    Maximum Input Voltage 32V for short period
    Insulation Resistance Minimum 50 M ohms @ 50VDC
    A graph showing the Operating Range

    Ordering Guidelines and Examples

    A > B > C > D

    MP 56B > 04 > 500G > 12

    A. Model (MP56) or (mp562) Model MP56B-04-500G-12 is a model MP56 Transducer specified with a B performance spec and a 1/4 NPT male fitting. The pressure range is 500 psi, with a 12ft Cable.
    B. Performance spec.
    C. Option:
      08= 1/8 NPT
      04= 1/4 NPT
    D. Pressure Range PSI
    E. Cable Length (other than 6ft.)

    Outline

    Pressure Fittings

    Available-Standard and Swagelock

    Schematic mV Output (MP562)

    Schematic 4-20 Output (MP56)